DIFFERENTIAL PRESSURE MODULE DPM™
Each DPM is custom con gured and optimized to your application.
Configuration for systems WITHOUT pressure transducers:
If you DO NOT have pressure sensors and need them please determine which of the two DPM kits is appropriate for your application:
Configuration for systems WITH pressure transducers:
If you DO have your own pressure sensors, please follow the part number scheme below to order your DPM control unit.
DPM – X X XXX
DPM-KS100 – This part number includes two cur-
rent output, single ended, 0-100 psi, Class 1, Division
1, pressure sensors (part number 764X021, pictured
below) supplied by Parker.
DPM-KD029 – This part number includes one current
output, differential, 0-2 Bar (0-29 psid), Class 1, Divi-
sion 1, pressure sensor (part number 764X008, pic-
tured below) supplied by Parker.
+
+
Sensor Options:
K = Sensors are supplied by Velcon (Kit)
0 = Sensors are not supplied
Sensor Confi gurations:
D = Current Output / Differential
S = Current Output / Single Ended
F = Voltage Output / Fixed
V = Voltage Output / Variable (0-5V)
Sensor High End Pressure Range (psi):
High end of sensor pressure range in psi.
Standard con gurations are 025, 029, 050 and 100.